Composite geomembrane
Widely used in water conservancy dams, traffic tunnels, roads, airports, drainage, housing, environmental protection and many other fields, in the project mainly play a role in seepage control, protection, reinforcement and so on.
Classification:
Contact number: 0086-18853141100
Contact E-mail: 18615171742@163.com
Business consultingDetailed introduction
Product specifications
1. One cloth and one film base cloth: 100 - 1000 g/m2Film thickness: 0. - 1.5mm;
2. Two cloth and one film base cloth: 80 - 600 g/m2Film thickness: 0.2 - 1.5mm;
3. One cloth and two film base cloth: 100- 1000 g/m2, film thickness: 0.1 - 0.8mm;
4. Multi-cloth multi-film base cloth: 100 - 1000 g/m2, film thickness: 0.1 - 0.8mm;
Performance characteristics
Good flexibility, in addition to geotextile isolation, drainage, reinforcement, protection and other functions, but also has a closed (anti-seepage) function.
Use Role
Widely used in water conservancy dams, traffic tunnels, roads, airports, drainage, housing, environmental protection and many other fields, in the project mainly play a role in seepage control, protection, reinforcement and so on.
Packing specification
Width 1-6m, length 50-100m (or according to user requirements)
Technical Index of Composite Geomembrane (GB/T 17642-2008)
| Project | Mass per unit area g/m² | |||||||||||||
| 400 | 500 | 600 | 700 | 800 | 900 | 1000 | 1100 | |||||||
| Nominal breaking strength/(KN/m) | 5 | 7.5 | 10.0 | 12.0 | 14.0 | 16.0 | 18.0 | 20.0 | ||||||
| 1 | Longitudinal and transverse rupture strength/(KN/m)≥ | 5 | 7.5 | 10.0 | 12.0 | 14.0 | 16.0 | 18.0 | 20.0 | |||||
| 2 | Elongation corresponding to standard strength in longitudinal and transverse direction/% | 30~100 | ||||||||||||
| 3 | CBR bursting strength/KN≥ | 1.1 | 1.5 | 1.9 | 2.2 | 2.5 | 2.8 | 3.0 | 3.2 | |||||
| 4 | Vertical and horizontal tear strength/KN | 0.15 | 0.25 | 0.32 | 0.40 | 0.48 | 0.56 | 0.62 | 0.70 | |||||
| 5 | Hydrostatic pressure resistance/MPa | According to Table 2 | ||||||||||||
| 6 | Puncturing strength N/cm | 6 | ||||||||||||
| 7 | Vertical permeability coefficient/(cm/s) | As per design or contract requirements | ||||||||||||
| 8 | Width deviation/% | -1.0 | ||||||||||||
| Project | Film thickness/mm | |||||||||||||
| 0.2 | 0.3 | 0.4 | 0.5 | 0.6 | 0.7 | 0.8 | 1.0 | |||||||
| Hydrostatic pressure resistance/MPa ≥ | a cloth a film | 0.4 | 0.5 | 0.6 | 0.8 | 1.0 | 1.2 | 1.4 | .6 | |||||
| two cloth and two film | 0.5 | 0.6 | 0.8 | 1.0 | 1.2 | 1.4 | 1.6 | .8 | ||||||
Note 1: The actual specification (nominal breaking strength) is between the adjacent specifications in the table, and the corresponding assessment index is calculated according to the linear interpolation method.
Note 2: In item 6, if the sample is difficult to peel off or does not reach the specified peel strength, the base material or film material shall be deemed to meet the requirements.
Note 3: The standard value of Item 8 is based on design or agreement.
Note 4: When the actual breaking strength is lower than the standard strength, the elongation corresponding to the standard strength shall not be judged for conformity.